MILROYAL® D series metering pumps are ideal metering technology where chemical injection is required for critical processes in oil and gas, chemical and hydrocarbon processing, water and wastewater treatment and most industries.

  • Material (liquid end): 316SS / Alloy 20 / Alloy C22 / PVC*
  • Pressure max: 3,495 psi / 241 bar (metallic liquid end); 150 psi / 10 bar (plastic liquid end); 3,000 psi / 207 bar (packed plunger)
  • Flow max: 53 gph / 200 lph (metallic liquid end); 34.1 gph / 129 lph (plastic liquid end); 12.497 gph / 47.31 lph (packed plunger)
  • Multiplex: Available
  • Flow variation control: Manual / Remote
  • Certifications: API 675, EC, ATEX, IECEX

*PVC liquid ends are not available with packed plunger type

This product is not available in India.

Modular Pump Design

Flexible modular construction supports various liquid ends and configurations, allowing precise customization for your process needs.

Precision Performance Range

Three frame sizes provide accurate chemical dosing across a wide spectrum of pressures and flow capacities.

Multiplex Configurations

Combine identical or mixed frames to enhance flexibility and adapt to complex or evolving application requirements.

Oil & Gas Reliability

Built for extreme offshore environments, ensuring consistent injection of methanol, inhibitors, and other corrosive chemicals.

Pipeline Flow Optimization (DRA)

Field-proven DRA pumps deliver precise chemical injection to reduce turbulence and improve pipeline efficiency.

Chemical & Water Treatment

Designed for harsh chemicals and industrial water treatment, ensuring accurate dosing, operational reliability, and long-term cost savings.

TYPICAL PERFORMANCE

Packed Plunger

 

Plunger Diameter

Gear Ratio Code

Maximum Capacity

1/4 HP (0.25 kW)

1/3 HP (0.25 kW)

Maxmium Discharge Pressure

ml/H 

GPH

PSIG

BAR

PSIG

BAR

1/8 in (3 mm)

60

305

0.081

300

21

-

-

30

615

0.162

300

21

-

-

15

1,200

0.316

300

21

-

-

10

1,800

0.475

300

21

-

-

1/8 HP (3 mm)

60

125

0.033

3000

207

-

-

30

245

0.065

3000

207

-

-

15

480

0.126

3000

207

-

-

1/4 in (6 mm)

60

1,230

0.325

300

21

-

-

30

2,460

0.650

300

21

-

-

15

4,800

1.270

300

21

-

-

10

7,150

1.880

300

21

-

-

1/4 HP (6 mm)

60

495

0.131

3000

207

-

-

30

985

0.260

3000

207

-

-

15

1,920

0.508

3000

207

-

-

7/16 in (11 mm)

60

3,785

1.000

1000

69

-

-

30

7,570

2.000

1000

69

-

-

15

15,520

4.100

1000

69

-

-

10

23,090

6.100

1000

69

-

-

5/8 in (16 mm)

60

7,950

2.100

650

45

-

-

30

15,845

4.200

650

45

-

-

15

31,795

8.400

-

-

650

45

10

47,310

12.500

-

-

650

45

 

TYPICAL PERFORMANCE

High Performance Diaphragm

 

Plunger Diameter

Gear Ratio Code

Maximum Capacity

1/3 HP (0.25 kW)

1/2 HP (0.37 kW)

Maxmium Discharge Pressure

L/H

GPH

PSIG

BAR

PSIG

BAR

1 in (25 mm)

60

19.7

5.2

220

15

-

-

30

39.4

10.4

220

15

-

-

15

76.5

20.2

190

13

220

15

1 1⁄4 in (32 mm)

60

33.3

8.8

145

10

-

-

30

66.2

17.5

130

9

145

10

15

129

34.1

100

7

145

10

1½ in (11 mm)

60

51.5

13.6

70

5

-

-

30

103

27.2

70

5

-

-

15

200

53.0

-

-

70

5

 

NOTES:

1. Typical performance based on 1725 RPM, 60 hz motor. Derate flow rates for all other RPM speeds.

2. Plastic liquid ends are limited to 150 PSIG (10 Bar) @68°F (20°C) and are linearly derated to 65 PSIG (4 Bar) @ 140°F (60°C).

DRIVE DIMENSIONS

NOTES:

Base (shown as dotted lines) supplied only with HPD liquid end.

DRIVE DIMENSIONS-milroyal-d

PACKED PLUNGER LIQUID END DIMENSIONS

PACKED PLUNGER LIQUID END DIMENSIONS - milroyal-d

HIGH PERFORMANCE DIAPHRAGM (HPD) LIQUID END DIMENSIONS

Plunger Diameter

A (1)

B (1)

C

1 in (25 mm)

6 ½ in

(165 mm)

6 ½ in

(165 mm)

6 1⁄8 in

(156 mm)

1 1⁄4 in (32 mm)

1 ½ in (38 mm)

 

18 in & 14 in Diameter Plunger-milroyal-d

Plunger Diameter

A (1)

B (1)

C

D

1 in (25 mm)

4 13⁄16 in (122 mm)

4 13⁄16 in (122 mm)

7 7⁄8 in (200 mm)

1/2 in

1 1⁄4 in (32 mm)

5 7⁄32 in

(133 mm)

5 7⁄32 in

(133 mm)

7  5⁄6 in

(194 mm)

1/2 in

1 ½ in (38 mm)

 

NOTES:

1. A & B dimensions are based on standard ball check configuration and single diaphragm, where metallic liquid end has single ball checks and plastic liquid end has double ball checks. Consult factory for dimensions on optional configurations.
7/16 in & 5/8 in Diameter Plunger-milroyal-d

PD3621-Milroyal-D Data Sheet.pdf

2.1 MB, PDF

54814_EN (1).pdf

542 KB, PDF

IOM_ACC-_1602101001_EN.pdf

1.1 MB, PDF

54146_HPD-Diagram-Milroyal-B-C-and-D IOM.pdf

2.9 MB, PDF

54261_Critical-service-liquid-end (1).pdf

1.3 MB, PDF

Milroyal-D-Plunger-ENG.pdf

1.3 MB, PDF

53941_Milroyal-D-with-Packed-Plunger IOM.pdf

1.4 MB, PDF

53870_Electronic-Capacity-Control.pdf

3.5 MB, PDF

339-0077-000-Metallic-Diaphragm-Liquid-End IOM (1).pdf

584 KB, PDF

54248_Milroyal-D-disc-diaphragm IOM.pdf

2.3 MB, PDF

MillRoyal C Animation

To load this content, approve your cookie preferences and allow the required cookies.

Our resources

Browse Technical Resources and Documentation for Your Equipment

Find everything you need in one place with our document library - organized, secure, and built for fast access to critical files.

Learn more

Document LibraryFind a Sales Rep