GSD PTFE DIAPHRAGM LIQUID END

Les pompes doseuses compactesPRIMEROY L (PLG)offrent une fiabilité et une sécurité de dosage inégalées pour tout type de fluide grâce à leur conception GSD unique et brevetée.
Fully compliant with API 675 and major global standards (ATEX, IECEx, NACE), ensuring safe and reliable operation in critical industrial environments worldwide.
Micrometric stroke adjustment enables accurate, repeatable dosing from 0–100%, even during operation, ensuring process stability and flexibility.
Triple hydraulic security by a valve blocking the overrunning and the extrusion. Installation Monitoring Indicator (IMI) system with the GSD design. One unique oil design for mechanical lubrication and hydraulic chamber: no risk of oil cross contamination
Diaphragm liquid ends guaranteed leak-proof with service life in excess of 20,000 hours
Highly adaptable with multiple liquid ends, valves, and control options, allowing precise configuration for specific process requirements.
Ensured by using high quality materials engineered to a robust and proven construction, oil bath lubrication to ensure reliability during continuous operation
| Moteur à 50 Hz | Moteur à 60 Hz |
|---|---|---|
débit | Jusqu'à 3 300 L/h | Jusqu'à 871 GPH |
Pression | Jusqu'à 45 bars | Jusqu'à 652 PSI |
Poussée | 900 daN | 2 023 lbf |
100 % d'accident vasculaire cérébral | 50 mm | 1.97 in |
Température ambiante standard | de -10 à +50 °C | de +14 à +122 °F |
Conception pour basses températures | de -40 à +50 °C | - 40 à + 122 °F |

La série PLG assure un dosage précis d'un large éventail de fluides utilisés dans de nombreux procédés industriels grâce à sa conception modulaire, qui propose plusieurs types d'embouts de dosage, des options de régulation du débit et d'autres possibilités de configuration, lui permettant ainsi de répondre aux exigences spécifiques de votre application industrielle.
Les principaux avantages du PLG résident dans sa conception compacte particulière, le dispositif de sécurité global (GSD) et l'indicateur de surveillance de l'installation (IMI).
Le modèle PLG est conçu pour des débits élevés (3 300 L/h – 871 GHP pour une configuration simplex) et des applications à pression moyenne (45 bar – 652 psi).
|
|
| Moteur 50 Hz | Moteur 60 Hz |
| |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
Code du diamètre du piston | Volume balayé | Vitesse maximale de nage | Vitesse maximale du moteur | Débit maximal | Pression maximale | Vitesse maximale de nage | Vitesse maximale du moteur | Débit maximal | Pression maximale | Raccordements | ||
10 bar | P.max | 145 psi | P.max | |||||||||
Ø | cm3 | spm | tr/min | l/h | Bars | spm | tr/min | GPH | psi | |||
Métallique, type H | ||||||||||||
40 | 62.8 | 149 | 1440 | 506 | 452 | 45 | 144 | 1728 | 129 | 115 | 652 | 1” - VV1 m |
50 | 98.2 | 149 | 1440 | 807 | 722 | 45 | 144 | 1728 | 206 | 184 | 652 | 1” - VV1 m |
63 | 155.9 | 149 | 1440 | 1254 | 1205 | 23 | 144 | 1728 | 320 | 307 | 333 | 2” - VV1 m |
70 | 192.4 | 149 | 1440 | 1582 | 1520 | 23 | 144 | 1728 | 404 | 388 | 333 | 2” - VV1 m |
80 | 251.3 | 149 | 1440 | 2067 | 2023 | 17 | 144 | 1728 | 527 | 516 | 246 | 2” - VV1 m |
90 | 318.1 | 149 | 1440 | 2616 | 2584 | 14 | 144 | 1728 | 668 | 661 | 203 | 2” - VV1 m |
100 | 392.7 | 149 | 1440 | - | 3300 | 11 | 144 | 1728 | - | 842 | 159 | 2” - VV1 m |
Plastique, type P | ||||||||||||
50 | 98,2 | 149 | 1440 | 807 | 10 | 144 | 1728 | 206 | 145 | 1” - VV1 f | ||
63 | 155,9 | 149 | 1440 | 1254 | 10 | 144 | 1728 | 320 | 145 | 1” 1/2 - VV1 f | ||
70 | 192,4 | 149 | 1440 | 1582 | 10 | 144 | 1728 | 404 | 145 | 1” 1/2 - VV1 f | ||
80 | 251,3 | 149 | 1440 | 2067 | 10 | 144 | 1728 | 527 | 145 | 1” 1/2 - VV1 f | ||
90 | 318,1 | 6 x 160 | 1440 | 2107 | 10 | 115 | 1728 | 534 | 145 | 1” 1/2 - VV1 f | ||
100 | 392,7 | 6 x 160 | 1440 | 2657 | 10 | 115 | 1728 | 674 | 145 | 1” 1/2 - VV1 f | ||

We will help you to identify the right solution for your application, operating conditions and performance requirements

Version | Poids net (*) | Poids brut (*) | Emballage | |||
|---|---|---|---|---|---|---|
kg | lbs | kg | lbs | (L x l x H) mm | (L x l x H) en | |
PLG - Simplex | 220 | 485 | 310 | 683 | 1100 x 680 x 1350 | 43.3 x 26.8 x 53 |
PLG - Duplex | 330 | 728 | 460 | 1.414 | 1600 x 950 x 900 | 63 x 37.4 x 35.5 |
PLG - Triplex | 470 | 1.036 | 660 | 1.455 | 1950 × 950 × 900 | 76,8 x 37,4 x 35,5 |
(*) Environ


Coagulation/flocculation (injection of ferric chloride, aluminium sulphate, etc.), pH regulation (injection of acids and alkalis), water conditioning before and/or after RO treatment in desalination plant
protection of installation such as boilers and hydraulic systems (corrosion inhibitors, biocides, scale inhibitors, amines…)
injection of additives, injection of co-catalyst, injection of sulphuric acid into water to produce diluted sulphuric acid

Injection of chemicals for separation and treatment of refined products, injection of paraffin inhibitor into fuel storage tanks
injection of biocide, corrosion/scale inhibitors, H2S scavengers… protecting piping and other assets and maintaining production rates, transfer of steam condensate
Injection of enzymes in starch production, injection of caustic soda for process water neutralization in refining and distilling applications
Pour charger ce contenu, approuvez vos préférences de cookies et autorisez les cookies requis.