Products
Metering Pumps
Process Pumps
Mixers
Systems & Skids
Electronics and Metering
Valves and Accessories
Industries & Applications
Water Treatment
Energy
Mining & Mineral Processing
Chemical Industry
General industry
Technology
Metering Pump Technology
Metering Pump Principles
Resources
Document Library
White Paper
Case Studies
Webinars on Demand
Digital Support Files
Certifications
Milton Roy YouTube Channel
Sales Terms & Conditions
About Us & Support
Spare Parts Inventory
CARE Maintenance Plans
News
Careers
Back to the product list

Advanced Designs for Critical Applications | Milroyal B

The MILROYAL B metering pump is a robust industrial duty metering pump for use in critical processes in oil and gas, chemical and hydrocarbon processes, water and waste treatment, and in most industries where chemical injection is required.

  • Material (liquid end): 316SS / Alloy 20 / Alloy C22 / PVC (*)
  • Pressure max: 3,675 psi / 250 bar (metallic liquid end); 150 psi / 10 bar (plastic liquid end); 10,000 psi / 690 bar (packed plunger)
  • Flow max: 626 gph / 2,370 lph (metallic liquid end); 119 gph / 450 lph (plastic liquid end); 245 gph / 927 lph (packed plunger)
  • Multiplex: Available
  • Flow variation control: Manual / Remote
  • Certifications: API 675, EC, ATEX, IECEX

This product is not available in India.

Modular Design Flexibility

Advanced modular construction supports a wide variety of liquid ends and options, enabling precise customization for specific process requirements.

Adaptable Process Performance

Efficiently handles diverse fluids, pressures, and flow rates, making it suitable for a broad range of demanding industrial applications.

Multiplex System Capability

Multiplex configurations allow multiple pumps to operate together, increasing performance, reliability, and operational flexibility.

Oil & Gas Durability

Designed for harsh offshore environments, delivering consistent injection of methanol, inhibitors, and other corrosive chemicals in extreme conditions.

Pipeline Efficiency (DRA)

Field-proven for drag reducer agent injection, optimizing pipeline flow by reducing turbulence at key network points.

Chemical & Water Processing

Ensures accurate dosing of harsh chemicals in petrochemical and water treatment processes, supporting compliance and long-term cost efficiency.

HIGH PERFORMANCE DIAPHRAGM (HPD) LIQUID END PERFORMANCE

Typical performance based on 1725 RPM, 3 Phase*, 60 Hz motor. Derate flow rates for all other RPM speeds.

 

Plunger Diameter

Gear Ratio Code

SPM @1725 RPM

Maximum Capacity*

1/3 HP (0.25 kW)

1/2 HP (0.37 kW)

3/4 HP (0.55 kW)

1 HP (0.75 kW)

1 1/2 HP (1.1 kW)

2 HP (1.5 kW)

Maximum Discharge Pressure*

GPH

L/H

PSIG

BAR

PSIG

BAR

PSIG

BAR

PSIG

BAR

PSIG

BAR

PSIG

BAR

7/16 in (11 mm)

8K

49

2.1

7

3,440

237

3,675

250

-

-

-

-

-

-

-

-

8J

70

3.0

11

1,625

112

3,215

222

3,675

250

-

-

-

-

-

-

8H

95

4.0

15

1,110

77

2,440

168

3,675

250

-

-

-

-

-

-

8G

113

4.9

18

775

53

1,905

131

3,675

250

-

-

-

-

-

-

8F

140

6.1

23

575

40

1,475

102

2,950

203

3,675

250

-

-

-

-

9/16 in (14 mm)

8K

49

3.8

14

1,730

118

2,780

189

3,675

250

-

-

-

-

-

-

8J

70

5.4

20

975

66

1,830

124

2,750

187

3,675

250

-

-

-

-

8H

95

7.3

28

650

44

1,350

92

2,030

138

3,055

208

3,675

250

-

-

8G

113

8.7

33

500

34

1,125

77

1,700

116

2,730

186

3,675

250

-

-

8F

142

11

42

375

26

900

61

1,350

92

2,400

163

3,600

245

3,675

250

5/8 in (16 mm)

8K

49

7.5

20

1,675

115

2,795

193

3,150

217

-

-

-

-

-

-

 

8J

70

7.5

28

755

52

1,170

104

2,700

217

2,885

217

-

-

-

-

 

8H

95

10.2

38

510

35

1,170

104

1,755

145

2,885

199

3,150

217

-

-

 

8G

113

12.2

46

340

23

910

63

1,755

121

2,390

165

3,150

217

-

-

 

8F

142

15.3

57

240

17

700

48

1,445

100

1,930

133

2,895

200

3,150

217

1 in (25 mm)

8K

49

14

53

545

38

875

60

1,250

86

-

-

-

-

-

-

8J

70

19

72

305

21

575

40

860

59

1,250

86

-

-

-

-

8H

95

26

98

205

14

420

29

635

44

955

66

1,250

86

-

-

8G

113

31

117

160

11

355

24

535

37

850

59

1,250

86

-

-

8F

142

39

148

120

8

285

20

425

29

755

52

1,130

78

1,250

86

1 1⁄4 in (32 mm)

8K

49

21

79

354

24

555

38

770

53

-

-

-

-

-

-

8J

70

30

114

195

13

365

25

550

38

770

53

-

-

-

-

8H

95

40

151

130

9

270

19

405

28

610

42

770

53

-

-

8G

113

48

182

100

7

225

16

340

23

545

38

770

53

-

-

8F

142

61

231

75

5

180

12

270

19

480

33

720

50

770

53

1½ in (38 mm)

8K

49

34

129

220

15

350

24

500

34

-

-

-

-

-

-

8J

70

48

182

120

8

230

16

345

24

500

34

-

-

-

-

8H

95

65

246

80

6

170

12

255

18

385

27

500

34

-

-

8G

113

77

291

60

4

140

10

215

15

340

23

500

34

-

-

8F

142

97

367

45

3

110

8

170

12

300

21

455

31

500

34

2 in (51 mm)

8K

49

52

197

140

10

225

16

300

21

-

-

-

-

-

-

8J

70

75

284

75

5

145

10

220

15

300

21

-

-

-

-

8H

95

101

382

50

3

105

7

160

11

245

17

300

21

-

-

8G

113

120

454

-

-

90

6

135

9

220

15

300

21

-

-

8F

142

151

572

-

-

70

5

105

7

190

13

300

21

-

-

2 1⁄2 in (64 mm)

8K

49

83

314

85

6

140

10

165

11

-

-

-

-

-

-

8J

70

119 4

50

50

3

90

6

140

10

165

11

-

-

-

-

8H

95

161

609

-

-

65

4

100

7

155

11

165

11

-

-

8G

113

191

723

-

-

55

4

85

6 1

35

9

165

11

-

-

8F

142

240

908

-

-

-

-

65

4

120

8

165

11

-

-

3 1⁄2 in (89 mm)

8K

49

170

643

-

-

70

5

100

7

-

-

-

-

-

-

8J

70

242

916

-

-

-

-

65

4

100

7

-

-

-

-

8H

95

330

1249

-

-

-

-

50

3

75

5

100

7

-

-

8G

113

391

1,480

-

-

-

-

-

-

65

4

100

7

-

-

8F

142

500

1,892

-

-

-

-

-

-

60

4

90

6

100

7

4 in (102 mm)

8K

49

216

820

-

-

50

3

75

5

-

-

-

-

-

-

8J

70

308

1,165

-

-

-

-

50

3

75

5

-

-

-

-

8H

95

419

1,585

-

-

-

-

-

-

60

4

75

5

-

-

8G

113

498

1,885

-

-

-

-

-

-

50

3

75

5

-

-

8F

142

626

2,370

-

-

-

-

-

-

45

3

70

5

75

5

Capacities listed are for discharge pressures up to 200 PSIG (14 Bar).

Capacity will decrease 0.8% for each 100 PSIG (7 Bar) over 200 PSIG (14 Bar).

NOTES: 

*  For single phase motors, increase horsepower by one size — example: increase ½ hp (0.37kW) to ¾ hp (0.55kW).

 † Plastic liquid ends are limited to 150 PSIG (10 Bar) @ 68°F (20°C) and are linearly derated to 65 PSIG (4 Bar) @ 140°F (60°C).

 ‡ Derate capacity by 5% when applying a diaphragm rupture detection system.

Plunger Diameter

Gear Ratio Code

SPM @1725 RPM

Maximum Capacity*

1/3 HP (0.25 kW)

1/2 HP (0.37 kW)

3/4 HP (0.55 kW)

1 HP (0.75 kW)

1 1/2 HP (1.1 kW)

2 HP (1.5 kW)

Maximum Discharge Pressure*

GPH

L/H

PSIG

BAR

PSIG

BAR

PSIG

BAR

PSIG

BAR

PSIG

BAR

PSIG

BAR

7/16 in (11 mm)

8K

49

2.1

7

3,440

237

3,500

241

-

-

-

-

-

-

-

-

8J

70

3.0

11

1,625

112

3,215

222

3,500

241

-

-

-

-

-

-

8H

95

4.0

15

1,110

77

2,440

168

3,500

241

-

-

-

-

-

-

8G

113

4.9

18

775

53

1,905

131

3,500

241

-

-

-

-

-

-

8F

140

6.1

23

575

40

1,475

102

2,950

203

3,500

241

-

-

-

-

5/8 in (16 mm)

8K

49

5.3

20

1,675

115

2,795

193

3,150

217

-

-

-

-

-

-

8J

70

7.5

28

755

52

1,515

104

2,700

186

3,150

217

-

-

-

-

8H

95

10.2

38

510

35

1,170

81

2,100

145

2,885

199

3,150

217

-

-

8G

113

12.2

46

340

23

910

63

1,755

121

2,390

165

3,150

217

-

-

8F

142

15.3

57

240

17

700

48

1,445

100

1,930

133

2,895

200

3,150

217

7/8 in (22 mm)

8K

49

9.6

36

800

55

1,385

95

1,500

103

-

-

-

-

-

-

8J

70

13.8

52

350

24

750

52

1,320

91

1,500

103

-

-

-

-

8H

95

18.6

70

225

16

560

39

1,025

71

1,500

103

-

-

-

-

8G

113

22.0

83

140

10

425

29

850

59

1,205

83

1,500

103

-

-

8F

142

27.6

104

90

6

345

24

740

51

985

68

1,500

103

-

-

1 1⁄8 in (28 mm)

8K

49

16.2

61

460

32

810

56

900

62

-

-

-

-

-

-

8J

70

23.0

87

185

13

430

30

770

53

900

62

-

-

-

-

8H

95

31.4

118

115

8

310

21

590

41

900

62

-

-

-

-

8G

113

37.0

140

65

4

230

16

485

33

720

50

900

62

-

-

8F

142

47.5

179

35

2

185

13

420

29

595

41

900

62

-

-

1 ½ in (38 mm)

8K

49

28.5

107

2

40

17

17

435

30

500

34

-

-

-

-

8J

70

41.0

155

90

6

225

16

420

29

500

34

-

-

-

-

8H

95

56.0

212

45

3

160

11

315

22

500

34

-

-

-

-

8G

113

67.0

253

-

-

115

8

255

18

400

28

500

34

-

-

8F

142

84.0

317

-

-

90

6

225

16

335

23

500

34

-

-

1 3⁄4 in (44 mm)

8K

49

39.0

147

175

12

320

22

360

25

-

-

-

-

-

-

8J

70

55.8

211

55

4

155

11

295

20

360

25

-

-

-

-

8H

95

76

287

-

-

110

8

225

16

360

25

-

-

-

-

8G

113

91

344

-

-

75

5

180

12

270

19

360

25

-

-

8F

142

114

431

-

-

60

4

155

11

220

15

360

25

-

-

2 1⁄2 in (64 mm)

8K

49

83

314

70

5

145

10

165

11

-

-

-

-

-

-

8J

70

119 

451

-

-

60

4

135

9

165

11

-

-

-

-

8H

95

161

609

-

-

40

3

95

7

165

11

-

-

-

-

8G

113

190

719

-

-

-

-

70

5

125

9

165

11

-

-

8F

142

240

908

-

-

-

-

65

4

95

7

165

11

-

-

Capacities listed are for discharge pressures up to 1,000 PSIG (69 Bar).

Capacity will decrease 1.0% for each 100 PSIG (7 Bar) over 1,000 PSIG (69 Bar).

NOTES:

*  For single phase motors, increase horsepower by one size — example: increase ½ hp (0.37 kW) to ¾ hp (0.55 kW).

†  Plastic liquid ends are limited to 150 PSIG (10 Bar) @ 68°F (20°C) and are linearly derated to 65 PSIG (4 Bar) @ 140°F (60°C).

HPD LIQUID END DIMENSIONS

 

Material

Plunger Diameter

 A‡

B‡

C*

D

in.

mm

in.

mm

in.

mm

in.

mm

in.

Metal (Double Ball) Standard

7⁄16

11

5 5⁄8

121

5 5⁄8

121

4

102

½

9⁄16

14

5 5⁄8

121

5 5⁄8

121

4

102

½

5⁄8

16

5 5⁄8

121

5 5⁄8

121

4

102

½

Metal (Single Ball) Standard

1

25

4 13⁄16

122

4 13⁄16

122

6 1⁄8

156

½

32

5 7⁄32

 133

5 7⁄32

133

6 1⁄8

156

½

38

7 1⁄16

179

7 1⁄16

179

8 1⁄4

210

1

2

51

7 9⁄16

192

7 9⁄16

192

8 1⁄4

210

1

64

7 9⁄16

192

7 9⁄16

192

8 1⁄4

210

1

89

10 1⁄8

257

10 1⁄8

257

13

330

4

102

10 1⁄8

257

10 1⁄8

257

13

330

Plastic (Double Ball) Standard

1

25

165

165

6 15⁄16

176

½

32

165

165

6 15⁄16

176

½

38

9 9⁄16

243

9 9⁄16

243

222

1

2

51

9 9⁄16

243

9 9⁄16

243

222

1

64

9 9⁄16

243

9 9⁄16

243

222

1

89

16‡

406‡

13

330

13¼‡

337‡

4

102

16‡

406‡

13

330

13¼‡

337‡

Notes:

*  Dimensions shown are for single diaphragm liquid ends. Contact factory for double diaphragm dimensions.

†  A & B dimensions are based on standard ball check configuration: Consult factory for dimensions on optional configurations.

‡  Suction and discharge connections are horizontal in metal and vertical in plastic except on plastic 3½ in (89 mm) plunger & 4 in (102 mm) plunger, where suction is horizontal, discharge is vertical and dimension “C” for discharge is 1013⁄16 in (275 mm).

HPD LIQUID END DIMENSIONS - milroyal-b

DISC DIAPHRAGM LIQUID END DIMENSIONS*

 

Material

Plunger Diameter

I

J

K

L

in.

mm

in.

mm

in.

mm

in.

mm

in.

Metal

7⁄16

11

4 3⁄4

121

140

3

76

½

5⁄8

16

4 3⁄4

121

140

3

76

½

7⁄8

22

5 3⁄4

146

6 7⁄8

175

3 7⁄16

87

1

1 1⁄8

28

5 3⁄4

146

6 7⁄8

175

3 7⁄16

87

1

38

6 7⁄16

164

7 15⁄16

202

3 5⁄8

92

1 1⁄4

1 3⁄4

44

6 7⁄16

164

7 15⁄16

202

3 5⁄8

92

1 1⁄4

64

6 15⁄16

176

10 5⁄16

265

3 7⁄8

98

Plastic

7⁄16

11

4 11⁄16

119

5 7⁄16

138

3 3⁄16

81

½

5⁄8

16

4 11⁄16

119

5 7⁄16

138

3 3⁄16

81

½

7⁄8

22

5 1⁄4

133

6 3⁄8

162

89

1

1 1⁄8

28

5 1⁄4

133

6 3⁄8

162

89

1

38

6 15⁄16

176

8 7⁄16

214

3 7⁄8

98

1 1⁄4

1 3⁄4

44

6 15⁄16

176

8 7⁄16

214

3 7⁄8

98

1 1⁄4

64

7 7⁄16

189

10 15⁄16

278

4 1⁄16

103

Notes:

*  Dimensions shown are for single diaphragm liquid ends. Contact factory for double diaphragm dimensions.

DISC DIAPHRAGM LIQUID END DIMENSIONS - milroyal-b

PD3641-Milroyal-B Data Sheet.pdf

2.4 MB, PDF

54126 - Pressure Style Leak Detection - Milroyal, Centrac B and Maxroy.pdf

2.5 MB, PDF

54814_EN (1).pdf

542 KB, PDF

Milroyal-B-ENG_.339-0065-000.pdf

850 KB, PDF

53940_Milroyal-B-drive IOM.pdf

3.6 MB, PDF

IOM_ACC-_1602101001_EN.pdf

1.1 MB, PDF

54146_HPD-Diagram-Milroyal-B-C-and-D IOM.pdf

2.9 MB, PDF

54261_Critical-service-liquid-end (1).pdf

1.3 MB, PDF

53870_Electronic-Capacity-Control.pdf

3.5 MB, PDF

339-0077-000-Metallic-Diaphragm-Liquid-End IOM (1).pdf

584 KB, PDF

54147_Milroyal-B-Pneumatic-Capacity-Control.pdf

1.6 MB, PDF

54145_Milroyal-B-C-disc-diaphragm IOM.pdf

2.7 MB, PDF

54149_Milroyal-B-HPD-Low-Flow IOM.pdf

2.0 MB, PDF

MillRoyal C Animation

To load this content, approve your cookie preferences and allow the required cookies.

Our resources

Browse Technical Resources and Documentation for Your Equipment

Find everything you need in one place with our document library - organized, secure, and built for fast access to critical files.

Learn more

Document LibraryFind a Sales Rep